# KAWS 5 ft (v59, straight): print queue, everything on the 0.4 nozzle

Files: `FINAL_PRINT_FILES\<job>_<pieces>.gcode.3mf`. Same list, with tracking, on the Moneymaker Console.

Both printers use a 0.4 nozzle. The order is one sequence dealt to whichever printer frees up first; if you run one printer, go A01, B01, A02, B02 ... in the order the console shows.

**Gates.** T0 = the pin clearance test passed (holds every job). LOCK = the lock, hatch, hinge and key tests passed.

**After printing:** pin holes and channel mouths on each piece's bed face are capped by a 0.5 mm skin: twist an 8 mm bit to the bottom of each pin hole, poke each channel mouth open.

## Tests (first)

| Job | What | Time | Grams | Note | Done |
|---|---|---|---|---|---|
| TA1 | T0 clearance pin + lock/hatch pins and heads + 6 joint pins | 0h51 | 18.8 | print first: makes the pin heads for the two test pauses | ☐ |
| TB1 | T0 clearance block | 0h19 | 13.5 | with TA1: the 20-minute pin clearance test | ☐ |
| TA2 | T1 lock: door top | 2h39 | 88.2 |  | ☐ |
| TB2 | T1 lock frame (body) | 2h48 | 127.8 | PAUSE at the first layer above 20.9 mm: drop both pin heads in, magnet end DOWN | ☐ |
| TA3 | T2 hatch (the real hatch) + T3 key plate | 1h25 | 57.1 | PAUSE at the first layer above 16.2 mm: drop both hatch-pin heads in, magnet end UP | ☐ |
| TB3 | T2 hatch floor (body) | 2h45 | 89.9 |  | ☐ |
| TA4 | T4 hinge: door bottom | 1h09 | 41.4 |  | ☐ |
| TB4 | T4 hinge sill (body) | 1h07 | 45.9 |  | ☐ |

| FIX1 | 8 transfer pins (mark the holes to drill on A01-A03, see the notes) | 0h20 | 6 | | ☐ |

## Printer A (0.4 nozzle): 170 h, 7.8 kg

| Job | Pieces | Gate | Time | Grams | Supports | Note | Done |
|---|---|---|---|---|---|---|---|
| A01 | P39 facelo_R | T0 | 6h46 | 246.2 | 8.2 g | PRINTED from the old file: drill its 3 holes on the face that meets P44 (transfer pins from P44) | ☐ |
| A02 | P40 facelo_L | T0 | 5h07 | 205.2 | 1.6 g | PRINTED from the old file: drill its 3 holes on the face that meets P41 (transfer pins, after P41 prints) | ☐ |
| A03 | P44 facehi_R | T0 | 6h23 | 285.7 | none | PRINTED from the old file: drill its 3 holes on the face that meets P45 (transfer pins, after P45 prints) | ☐ |
| A04 | P46 facehi_L | T0 | 9h51 | 558.4 | none | REPRINT with this file: the first try (lightning infill) failed when its wire-channel tube fell over. This file has its pin holes, nothing to drill; infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A05 | P02 heel_R | T0 | 17h59 | 744.3 | 62.9 g | pull the supports out of the ballast chamber before gluing | ☐ |
| A06 | P04 toe_L | T0 | 18h12 | 717.0 | 70.5 g | pull the supports out of the ballast chamber before gluing | ☐ |
| A07 | P09 shorts_front_R | T0 | 9h12 | 564.6 | 3.3 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A08 | P10 shorts_back_R | T0 | 3h52 | 176.8 | 6.1 g |  | ☐ |
| A09 | P15 bfR | T0 | 3h22 | 181.6 | none |  | ☐ |
| A10 | P13 bmR | T0 | 2h53 | 152.5 | none |  | ☐ |
| A11 | P14 bbR | T0 | 0h59 | 46.0 | none |  | ☐ |
| A12 | P19 bbL | T0 | 1h03 | 49.6 | none |  | ☐ |
| A13 | P25 arm_R | T0 | 5h29 | 255.5 | 11.3 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A14 | P24 cuff_R | T0 | 3h56 | 130.5 | 5.6 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A15 | P21 glove_L | T0 | 15h36 | 542.5 | 45.2 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A16 | P16 belly_mid | LOCK | 14h10 | 751.7 | 36.1 g | supports inside the lower vault: pull them out from below; infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A17 | P23 cash | LOCK | 12h43 | 468.4 | 48.6 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A18 | P28 vR_front | T0 | 0h57 | 40.3 | none |  | ☐ |
| A19 | P31 vL_front | T0 | 1h00 | 44.0 | none |  | ☐ |
| A20 | P27 vR_back | T0 | 5h34 | 272.7 | none | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A21 | P33 armtop_R | T0 | 1h40 | 85.2 | none |  | ☐ |
| A22 | P36 SHO | T0 | 5h18 | 329.2 | none | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A23 | P43 earlo_L | T0 | 3h47 | 156.2 | 3.9 g |  | ☐ |
| A24 | P49 earhi_L | T0 | 4h09 | 184.9 | 5.6 g |  | ☐ |
| A25 | P41 backlo_L | T0 | 6h08 | 343.7 | 2.9 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| A26 | P47 backhi_L | T0 | 3h57 | 222.3 | none |  | ☐ |

## Printer B (0.4 nozzle): 171 h, 8.1 kg

| Job | Pieces | Gate | Time | Grams | Supports | Note | Done |
|---|---|---|---|---|---|---|---|
| B01 | PINS d8 x 23 (152 pcs, sheet 1) | T0 | 6h00 | 179.7 | off |  | ☐ |
| B02 | PINS d8 x 23 (150 pcs, sheet 2) | T0 | 5h55 | 177.3 | off |  | ☐ |
| B03 | P01 toe_R | T0 | 17h23 | 693.0 | 67.1 g | pull the supports out of the ballast chamber before gluing | ☐ |
| B04 | P03 heel_L | T0 | 19h59 | 791.0 | 77.4 g | pull the supports out of the ballast chamber before gluing | ☐ |
| B05 | P05 leg_lo_R | T0 | 6h11 | 396.4 | none | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B06 | P06 leg_lo_L | T0 | 6h18 | 402.7 | none | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B07 | P07 leg_hi_R | T0 | 5h24 | 341.2 | none | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B08 | P08 leg_hi_L | T0 | 5h43 | 359.3 | 2.0 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B09 | P12 shorts_front_L | T0 | 9h02 | 556.1 | 2.1 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B10 | P11 shorts_back_L | T0 | 3h59 | 179.5 | 6.3 g |  | ☐ |
| B11 | P18 bfL | T0 | 3h20 | 179.4 | none |  | ☐ |
| B12 | P20 bmL | T0 | 3h10 | 157.2 | none |  | ☐ |
| B13 | P26 arm_L | T0 | 5h36 | 283.4 | 11.2 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B14 | P22 glove_R | T0 | 12h20 | 487.6 | 26.6 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B15 | HW small parts (lock pins, heads, hatch pins, locating pins, fill caps; 3 sets of pins), PINS d6 x 19 (6 pcs, sheet 1), PINS d4 x 13 (8 pcs, sheet 1), PINS d5 x 15 (6 pcs, sheet 1) | LOCK | 0h50 | 17.7 | off | makes the lock and hatch pin heads used in the two pauses | ☐ |
| B16 | HW door | LOCK | 4h33 | 153.6 | 2.3 g |  | ☐ |
| B17 | HW hatch | LOCK | 1h04 | 44.4 | none | PAUSE: first layer above 16.2 mm, drop both hatch-pin heads in, magnet end UP. Skip this job if the test hatch (TA3) passed: it is the same part. | ☐ |
| B18 | P17 belly_back | LOCK | 8h26 | 391.9 | 57.2 g | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B19 | P30 vault_back | LOCK | 10h47 | 614.6 | ? | PAUSE: first layer above 14.9 mm, drop both lock-pin heads in, magnet end DOWN; infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B20 | HW cash lid + band underside, HW bay door | LOCK | 1h18 | 42.1 | none |  | ☐ |
| B21 | HW money band | LOCK | 1h51 | 49.8 | 8.1 g |  | ☐ |
| B22 | P29 vault_front | T0 | 4h29 | 237.3 | none |  | ☐ |
| B23 | P32 vL_back | T0 | 4h38 | 234.7 | none | infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B24 | P34 armtop_L | T0 | 2h00 | 90.1 | none |  | ☐ |
| B25 | P35 SHO_R | T0 | 0h57 | 44.1 | none |  | ☐ |
| B26 | P37 SHO_L | T0 | 1h04 | 49.4 | none |  | ☐ |
| B27 | P42 earlo_R | T0 | 3h02 | 136.3 | none |  | ☐ |
| B28 | P48 earhi_R | T0 | 4h09 | 183.7 | 4.0 g |  | ☐ |
| B29 | P38 backlo_R | T0 | 6h33 | 377.6 | 3.8 g | a thin support branch sits in the eye/nostril wire channels: run a rod or long 6 mm bit through them before gluing; infill is adaptive cubic: a wire channel or recess wall here stood alone in lightning infill (the way P46 failed) | ☐ |
| B30 | P45 backhi_R | T0 | 4h22 | 243.0 | none |  | ☐ |